Our Internet Data Center
GetMySiteOnline.com's equipment is colocated in a $15 million telco-grade data center owned and operated by Data Foundry and located in Austin, TX. Originally built in 2001 for Verio, this data center is fully redundant and secured in every way. It is monitored 24x7 by live personnel, and is scaled to meet growing demands far into the future. This is truly a first-class facility! See below for more on the specs of this data center.

Main Facility in Austin, TX
Personnel at check-in area matches government issued picture ID to recorded ID in the real-time “Approved Access Database” before access to the IDC is permitted
(20) 30-ton Liebert CRACs (Computer Room Air Conditioners) ensure constant temperature and humidity levels
Secured, lockable private cages available in multiple sizes
Individually keyed, lockable cabinets
Secure private suites for those with the strictest security and privacy requirements
Parallel, Redundant Uninterrupted Power Supplies (UPSs) can provide up to 30 minutes runtime at full load without assistance from Generators
Uninterrupted Power Supplies, Automatic Transfer Switches, Power Distribution Switchboards, Power Breakers
Redundant Power Distribution Switchboards condition and distribute power
Redundant Automatic Transfer Switches (ATSs) condition and distribute power from the dedicated 400 Megawatt Austin Energy electrical substation
Hand Key Biometric Access Control systems throughout entire Data Center
49 camera, color, IP-based CCTV surveillance system records full motion video to multiple Digital Video Recorders and take video clips upon every door opening
Four levels of fire suppression include a state-of-the-art FM-200, a non-conductive and non-corrosive gas system that is a safe alternative to halon
Dual Interlock, Dry Pipe, Pressurized Pre-action sprinkler system ensures no water above any equipment in the Data Center
Liebert Glycol Condensing Units (GCUs) provide over 1,000 tons of capacity and configured with N+4 redundancy
Redundant Caterpillar Diesel Generators start and sync to the UPS systems in under 10 seconds
Interior view of Caterpillar Diesel Generators. Generators start and sync to the UPS systems in under 10 seconds
Concrete filled, steel reinforced barriers and barbed wire fence surround exterior while external cameras monitor outside environment
Click pictures to enlarge. Hover over each image for more information.

Internet Data Center Specs
Real Estate Summary
Area
  • Total - 30,000 square feet
  • Total Raised Floor – 21,133 square feet
Power
UPS
  • (4) 500 kVA (expandable to six) PowerWare 9315 parallel, redundant UPS systems dedicated to the colocation area provide 30 minutes runtime at full load
  • (2) 80 kVA (expandable to 3) PowerWare parallel, redundant UPS systems provide additional UPS infrastructure dedicated to the POP
Generators
  • (2) 1875 kVA (1,500 KW) Caterpillar diesel generators. Prebuilt slab and electrical conduits provide expansion for third 1875 kVA generator
  • 6,000 gallon fuel capacity onsite allowing 48+ hours runtime at N+1
Utility
  • 400 Megawatt Austin Energy sub-station dedicated to Met Center. Fully prebuilt transformer pad provides expansion capabilities
  • (2) ASCO 3,000 AMP, 480 Volt parallel Automatic Transfer Switches (ATSs), each with redundant TVSS surge protectors
PDU's
  • PDI 150 kVA Power Distribution Units (PDUs) capable of 120 Volt and 220 Volt power
Grounding
  • Entire data center connected to grounding system
  • All external infrastructure protected by lightning protection system
Security
Internal
  • 50 camera, color, IP-based CCTV surveillance system records full-motion video to multiple DVRs and takes video clips upon every door opening
  • Hand Key Biometric Access Control System, individually keyed cabinets, cages and optional private suites provide maximum security and privacy
  • Man traps at all external doors prevent unauthorized access
External
  • Concrete filled, steel reinforced barriers surround exterior. Foundation is slab on grade with a 5-foot riser
  • Barbed wire fence surrounds external infrastructure
  • External cameras monitor outside environment
HVAC
CRAC's
  • (20) 30-ton Liebert CRACs (Computer Room Air Conditioners) with expansion to (30) 30- ton CRAC units
  • Constant temperature at 72 +/- 2 degrees and relative humidity at 50%
  • CRACs utilize non-water-based Glycol
Glycol
Condensing
Unit
  • (13) 78-ton Liebert Glycol Condensing Units (GCUs) – 1,014 tons of capacity
  • N+2 Redundancy - full operational mode is maintained in the event of failure of up to two of the twenty CRACs and up to two of the thirteen GCUs
  • (2) 50-ton HVAC units dedicated to UPS and Electric Rooms
Fire Prevention and Suppression
Phase 1 HSSD (High Sensitivity Smoke Detection) sensors continuously sample the air at adjustable periods of time for smoke, chemicals and heat. HSSD can detect fire up to 30 minutes prior to smoke and/or flame
Phase 2 Localize and Isolate the source and use FE36 handheld extinguishers
Phase 3 FM-200 building-wide system. (39) FM-200 systems are distributed across the entire Data Center. FM-200 non-conductive and non-corrosive gas prevents equipment damage that could
otherwise result from traditional water-based systems. FM-200 is a safe alternative to Halon
Phase 4 Dual Interlock, Dry Pipe, Pre-Action Sprinkler System. Pressurized dual interlock system ensures no water is above any equipment in the Data Center
Building Management Control
A building management system control monitors and reports any abnormal conditions within the Internet Data Center. This system can be remotely operated
Telco Fiber Facilities (at max capacity)
  • OC-48 - Time Warner
  • OC-48 - El Paso Global Networks
  • OC-48 - Qwest
  • OC-48 - Grande Communications
  • OC-12 - Southwestern Bell
Internet Infrastructure
  • (2) Cisco 12000 series routers
  • (2) Cisco Catalyst 6500 switches
  • Multi-homed, redundant connectivity to global upstream providers
Fight Back Against SPAM
  ConvertToJPG.com
  TheAfricanPalace.com
  AfricanBeautyCenter.com
  BearsCarpetCare.net
  LanPartyPa.net

Copyright © 2005, GetMySiteOnline.Com, All rights reserved         Privacy Policy         Acceptable Use Policy

On Windows Server 2003 Powered by Helm, The WebHosting Control System   
SPAMACIDE.com CHEAPSPAMKILLER.com EASYSPAMKILLER.com IGETTOOMUCHSPAM.com IHATESPAMMAIL.com INSTANTSPAMKILLER.com NEWSPAMKILLER.com SPAMABYSS.com SPAMAGENTS.com SPAMKILLERDOWNLOAD.com SPAMKILLERINFO.com SPAMKILLERPROGRAM.com SPAMKILLERREVIEW.com SPAMKILLERREVIEWS.com SUPERSPAMKILLER.com ABETTERGOVERNMENT.com CONVERTTOJPG.com CURTSCORNER.com CURTSWEBPAGE.com GETMYSITEONLINE.com MYGOVERNMENTONLINE.com SUMMERCAMPASSISTANT.com SUMMERCAMPMANAGER.com THEAFRICANPALACE.com THECAMPASSISTANT.com THECAMPMANAGER.com THECAMPMASTER.com THEONEPERCENTPLAN.com